Sign In | Join Free | My bushorchimp.com
China Hefei Chitherm Equipment Co., Ltd logo
Hefei Chitherm Equipment Co., Ltd
Verified Supplier

1 Years

Home > High Temperature Box Furnace >

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

Hefei Chitherm Equipment Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

Model Number : MBF40-10O

Range of Applications : Industrial

Type : Electric Holding Furnace

Usage : Ceramic Sintering

Fuel : Electric

Atmosphere : Air

Effective Chamber Dimensions : 330*200*660mm(W*H*D)

Furnace Chamber Size : 360*460*800mm(W*H*D)

Rated Temperature : 850°c

Thermocouple Type : K

Transport Package : Wooden Packaging

Specification : 1150*1970*1460mm(W*H*D)

Trademark : Chitherm

Origin : China

HS Code : 8514101000

Supply Ability : Customized

Customization : Available

Certification : ISO

Place Style : Vertical

Place of Origin : China

Brand Name : Chitherm

MOQ : 1

Price : Negotiable

Packaging Details : Customized

Delivery Time : Customized

Payment Terms : Customized

Contact Now

MBF40-10O 1100 ordm C Medium Temperature Box Furnace for Heating 330*200*660mm Effective Chamber Dimensions Electric Furnace
1.Model:MBF40-11O Medium Temperature Atmosphere Box Furnace

2.Application Fields: Primarily used for the sintering process of lithium battery cathode and anode materials, and also suitable for sintering processes of magnetic materials, electronic components, ceramics, and other products.

3. Mainly Specifics:
1. Rated Temperature: 850°C.
2. Maximum Temperature: 1100°C
3. Furnace Opening Size: 360mm × 220mm (Width × Height).
4. Furnace Chamber Size: 360mm × 460mm × 800mm (Width × Height × Depth).
5. Effective Size: 330mm × 200mm × 660mm (Width × Height × Depth).
6. Sagger Specification: 330mm × 100mm × 330mm (Width × Height × Depth).
7. Loading Method: Sagger supported by SiC rollers, double-layer and double-row arrangement.
8. Heating Elements: Silicon carbide rods inside ceramic tubes.
9 .Thermocouple Type: K-type.
10. Temperature Control Points: Upper and lower points for control, middle point for measurement.
11. Temperature Control Method: Imported temperature control module, control accuracy ±1°C, with PID parameter self-tuning function.
12. Heating Stages: 9 stages.
13. Oxygen Content Detection: Equipment reserved with oxygen content detection port (optional oxygen analyzer).
14. Pressure Detection: Real-time display of furnace pressure via digital differential pressure gauge.
15. Furnace Temperature Uniformity: ±3°C (tested at 850°C constant temperature with empty furnace and saggers, one thermocouple ring at the center of each sagger).
16. Exhaust Method: Exhaust chimney designed at the top of the furnace chamber, manually adjustable exhaust size.
17. Maximum Heating Power: ≤25kW
18.Surface Temperature Rise of Furnace Body: ≤40°C.
19 .Alarm Protection: Interlock between heating and furnace door operation, audible and visual alarms for overtemperature, thermocouple break, and low pressure.
20 .Reference External Dimensions: 1150mm × 1970mm × 1460mm (Width × Height × Depth, excluding chimney), actual dimensions subject to the specific product.

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

1. - Furnace frame
2. - Chimney
3. - Furnace chamber
4. - Furnace door
5. - Heating element
6. - Sagger (a type of ceramic container used in kilns)
7. - Roller bar (used in kilns for moving ceramics during the firing process)

4.Delivery List
Item Note QTY
Basic Compositions Furnace 1 PC
Certificates of Inspection Furnace and major purchased components 1 Set
Technical Documents Furnace specifications, technical documents of major purchased components, etc 1 Set
Key Parts Heating Elements ceramic tube-encased silicon carbide rod 1 Set
Temperature Controller Azbil 1 Set
touch screen 1 Set
Spares silicon carbide rod 1 PC

5. Facility Requirements
1 .Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
2 .Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 6 - 18m3 /h.
3 .Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 20m3 /h;
4 .Power conditions: capacity greater than 34kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;

5 .Installation site: 2500mm×2000mm×3000mm (W×H×D), installation area greater than 5m2.

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

Product Tags:

1100 Ordm C nitrogen furnace

      

Electrical nitrogen furnace

      

1100 Ordm C furnace electrical box

      
Buy cheap 1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating product

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Chitherm Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)